BPEI-Based N-Doped Carbon Dots with Sensitive and Selective Cu2+ Ion-Sensing Ability


Demirci S., Torres J. H., ŞAHİNER N.

Micromachines, cilt.16, sa.11, 2025 (SCI-Expanded, Scopus) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 16 Sayı: 11
  • Basım Tarihi: 2025
  • Doi Numarası: 10.3390/mi16111275
  • Dergi Adı: Micromachines
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Compendex, INSPEC, Directory of Open Access Journals
  • Anahtar Kelimeler: Cu2+ sensor, environmental water, fluorescence quenching, metal ion sensor, selective Cu2+ sensing
  • Çanakkale Onsekiz Mart Üniversitesi Adresli: Evet

Özet

In this research, we examined the potential sensor characteristics of branched polyethyleneimine (BPEI)-derived carbon dots (CDs) synthesized using BPEI as a nitrogen source and citric acid (CA) as a carbon source, specifically for the recognition of various metal ions. Among the BPEI CDs produced with different amounts of BPEI to CA BPEI:CA ratios of 0.5:1, 1:1, and 2:1 w/w, named as BPEI0.5 CD, BPEI1 CD, and BPEI2 CD, respectively. The BPEI0.5 CD, which contains the least BPEI, exhibited the highest fluorescence intensity: 50,300 a.u. in a 0.6 mg/mL solution were recorded as λem: 420 nm at λex: 360 nm and 600 V PMT voltage with 5 nm of slit width for both excitation and emission. We investigated the fluorescence variations in BPEI CD-based CDs in 2 mL solutions containing Cd2+, Co2+, Cu2+, Ni2+, and Pb2+ metal ions at various concentrations. Amongst these metal ions, the most pronounced sensitivity was noted for Cu2+ ions with a limit of detection (LOD) value of 0.39 ppm. For BPEI CDs created with BPEI:CA ratios of 0.5:1, 1:1, and 2:1 w/w, the sensitivity to Cu2+ ions increased with a higher BPEI ratio, with a LOD value of 0.30 ppm recorded for BPEI2 CDs. Moreover, Cu2+ ion solutions were prepared from various salts, including chloride, acetate, nitrate, and sulfate; aside from some fluorescence variation observed for BPEI0.5 CDs, no significant difference in BPEI CD fluorescence change was observed with the use of the various salt solutions of Cu2+ ion. In quenching experiments conducted on mixtures of Cd2+, Co2+, Cu2+, Ni2+, and Pb2+ metal ions with Cu2+, it was noted that BPEI CDs displayed selectivity for Cu2+ ions. Furthermore, the structures of BPEI CDs have been effectively utilized in real water samples, such as tap water and seawater, demonstrating a quenching capability of over 65% in the presence of 50 ppm Cu2+ ions.