Development and application of a sensitive, disposable and low-cost electrochemical sensing platform for an antimalarial drug: amodiaquine based on poly(calcein)-modified pencil graphite electrode


Karakaya S., Kartal B., Dilgin Y.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, ss.1-14, 2020 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Basım Tarihi: 2020
  • Doi Numarası: 10.1080/03067319.2020.1791332
  • Dergi Adı: INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Agricultural & Environmental Science Database, Aquatic Science & Fisheries Abstracts (ASFA), CAB Abstracts, Chemical Abstracts Core, Chimica, Compendex, Environment Index, Food Science & Technology Abstracts, Pollution Abstracts, Veterinary Science Database
  • Sayfa Sayıları: ss.1-14
  • Anahtar Kelimeler: Amodiaquine, antimalarial drug, calcein, pencil graphite electrode, differential pulse voltammetry, electrochemical sensor
  • Çanakkale Onsekiz Mart Üniversitesi Adresli: Evet

Özet

In this study, an electrochemical sensor towards the determination of an antimalarial drug, amodiaquine (Adqn), was performed. The proposed sensor was fabricated by electro-polymerisation of calcein (CCN) onto pencil graphite electrode (PGE). The electrochemical behaviour of 0.40 mM Adqn at both poly(calcein)-modified pencil graphite electrode (poly(CCN)/PGE) and bare PGE was evaluated in pH 3.0 Britton-Robinson buffer solution by cyclic voltammetry (CV) method. The voltammograms indicated that poly(CCN)/PGE presents a remarkable response towards oxidation and reduction of Adqn compared with PGE. The characterisation studies at poly(CCN)/PGE were performed by recording the electrochemical impedance curves, scanning electron microscopy images and energy-dispersive X-ray spectra. To determine the analytical performance of the poly(CCN)/PGE, the parameters such as linear range, limit of detection and sensitivity were determined based on the oxidation of Adqn by differential pulse voltammetry (DPV) method and were calculated to be 0.50-25 mu M, 0.16 mu M and 20.566 mu A mu M-1, respectively. The recovery studies at poly(CCN)/PGE were carried out with various matrixes (tap water, artificial blood and maternal milk) by DPV-spike methods, and the high recovery values (99.2-100.6%) confirmed that poly(CCN)/PGE can be used towards sensitive and accurate determination of Adqn in different sample matrixes containing Adqn.