Can ultrasonography be used to determine working length in endodontic treatment? An in vitro study


EREN İ., SARIYILMAZ Ö., EREN H., SARIYILMAZ E., Uslu G.

Odontology, cilt.112, sa.2, ss.453-459, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 112 Sayı: 2
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1007/s10266-023-00858-1
  • Dergi Adı: Odontology
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, MEDLINE
  • Sayfa Sayıları: ss.453-459
  • Anahtar Kelimeler: Electronic apex locator, Root apex, Root canal preparation, Ultrasound, Working length determination
  • Çanakkale Onsekiz Mart Üniversitesi Adresli: Evet

Özet

This study was conducted to evaluate efficacy of ultrasonography (USG) in determining working length in in-vitro conditions. Twenty five access cavities of maxillary incisor teeth were opened and actual working lengths (AWL) were measured with dental operating microscope. The working length were then measured with an electronic apex locator and USG. USG and apex locator measurements were statistically analyzed using one sample t-test and compared with AWL. The mean AWL measurment was 20.68 mm. USG measured the working length slightly longer (21.09 mm) than the measurements of apex locator (20.64 mm). Statistical analysis showed that the USG method provided similar measurements to electronic apex locators and with no statistical difference with actual working length (P <.05). USG emerges as a promising method for working length measurement that allows simultaneous visualization of root tip anatomy in cases where electronic apex locators may be insufficient and there is buccal cortical bone loss.